FFS-1072 Forecourt Guide 2025 2 - Flipbook - Page 32
UPP® PIPE ELECTROFUSION WELDING: C A B L E C H A R T
Connect the leads from the welding unit to the fittings per the chart below. The leads
should fit firmly. It is very important to use the correct cable. Before pushing the
start button, the welder must show a GREEN ready light. Hold the start button down
momentarily and then release it.
After the welder is turned on, press the start button to begin the welding process.
The weld time is determined by the welder and no further input is required. The
welder display will show welding progress.
Once completed it is good practice to write the time on the fitting to determine
when clamps can be removed. Wait 20 minutes for the weld to cool before removing
clamps. Always reset the welder between welds by depressing and holding the start
button for 3 seconds.
TYPE OF FITTING
WELDING
CABLE COLOR
SIZE OF
WELDING PIM
(MM)
CURRENT
(AMPS)
WELD TIME @
20°C
(SECONDS)
Primary
Red
4
4
184
Secondary
Green
2
5
80
Fusion Chamber
White
2.3
7
360
NOTES: