MAGVFC™/ ECOVFC™: U S E R I N T E R F A C E
User interface panel is the front panel located under the MagVFC™ cover.
PART
DESCRIPTION
Pump Status Display
Displays codes that indicate controller or pump status.
See the Troubleshooting section for details of codes.
Silence Alarm/
Fault Readout Button
Push and it will turn off audible alarm. Push and hold
button and the Pump Status Display will show the last
three fault conditions the MagVFC™ encountered.
Reset Button
Resets controller of any fault condition.
Communications LED
Used in Primary/Secondary type configurations to indicate
communication activity.
RS-485 Connection
Used in Primary/Secondary configurations.
(Frequency connection not used in IST-VFC Mode.)
Relay Contact
Normally open, the relay closes when the pump is running.
(Relay sold separately).
SW1 Operational
Pressure Switch
Adjusts the submersible pump’s operation pressure.
SW2 Address Switches
Used in Primary/Secondary type configurations.
SW3 Configuration Switches
Factory default settings for stand-alone use in gasoline.
See DIP Switch Setting section for other settings.
SW6 Configuration Switches
More configuration options.
See DIP Switch Setting section for specific settings.