Inputs & Connectivity
EVO™ 600
EVO™ 6000
Maximum tanks monitored
48 / 132*
72 / 168*
Maximum sensor input capacity
48 / 180*
108 / 244*
Maximum total inputs
72 / 276*
132 / 336*
14
Maximum AC input channels
36 / 72*
36 / 72*
13
Maximum relay output channels
26 / 50*
26 / 50*
12
Mini-USB
2
2
11
USB
10
ETH2
11” (290mm)
Connectivity
Ethernet (qty 2), RS-232, RS-485,
standard USB, Mini-B USB
Communication protocol support
MQTT, MODBUS®, XML, Veeder-Root®
GND TX RX
Wi-Fi
9
ETH1
Dry contact input channels
2
8
))H((
TECHNICAL SPECIFICATIONS
EVO™ 600 / 6000 CONSOLES
17
11¾”
(300mm)
12 1/8”
(308mm)
3
16
4
15
1
*Requires use of FMP-EXPC Expansion Consoles and/or FMP-MSH Multiplexing Sensor Hubs.
5
8 3/16”
(208mm)
Hardware
EVO™ 600 Dimensions
H: 11.75", W: 10¼", D: 9"
H: 300 mm, W: 260 mm, D: 229 mm
EVO™ 6000 Dimensions
H: 11.75", W: 16½", D: 9"
H: 300 mm, W: 419 mm, D: 229 mm
Display type
7" (17.78 cm) color LCD touch screen
Printer type
Thermal internal or external (network or USB)
Alarm
Internal audible alarm
LEDs
Alarm, warning, and power
Applicable liquids
Petroleum, chemicals, and waste
Power requirements
110 to 240 VAC, 50/60 Hz, 2.6 Amps
Operating temperature
32° to 104° F (0° to 40° C)
Humidity
0-90% non-condensing
1.
Cover
10. Ethernet Port 2
Approvals
UL, cUL, ATEX, IECEx, GSA IT Security
2.
LCD Touch Screen
11. USB Port (Type-A)
Third party certification of leak detection capabilities
3.
LED Indicators
12. USB Port (Mini-B)
4.
Printer
13. RS-232 Comm Port 1
5.
Mounting Tabs
14. WiFi
6.
Module Slots
15. Bus Extension
7.
Communication Ports
16. RS-232 Comm Port 2
8.
Annunciator (audible alarm)
17. RS-485 / TPI
9.
Ethernet Port 1
7
Certifications
Security
–
–
–
–
–
Customizable user roles / user activity tracking
Multi-factor authenticated log-in
Third party verified security
GSA IT security approval
Latest SSL/TLS protocols
6
43