2025 UL Ordering Catalog - Flipbook - Page 41
GUARDIAN SERIES™ FIXED
SPEED PUMP CONTROLLER
1
SUBMERSIBLE
PUMPING SYSTEMS
ORDERING INFORMATION
Guardian Series™ Single Phase Controller
2
Model
Description
5800100220
SPGC-220 Guardian Series™ Single-Phase Controller,
220 Volt
402312931
STP-DHI + SPGC-220 Guardian Series™ Single-Phase
Controller bundle (220 Volt supply, 110 Volt hook)
SPECIFICATIONS
Notes:
1. Compatible with all single-phase FE PETRO® and competitive model STPs.
Dimensions
8½" × 5" × 3" (215 mm × 127 mm × 76 mm)
3. Compatible for use in primary/secondary configurations with STP-SCI models.
Motor
contact rating
2 Hp, 200-250 VAC, 50/60 Hz, Single Phase
Replacement Parts
Switch
hook rating
120-240 VAC, 50/60 Hz
Com port
An integrated RS 485 com port is provided to
connect Guardian Series™ Controllers to EVO™ Series
Consoles for enhanced functionality via Turbine
Pump Interface (TPI)
Approvals /
Certifications
–
–
–
2. One controller required for each submersible (up to 2 Hp).
Item
Model
Description
1
225000932
SPGC-220 upper (user input)
replacement board
2
225005932
SPGC-220 lower (power, relay)
replacement board
cULus listed
CE certified
ISO 9001:2015 certified manufacturer
Capabilities
Capability
Standard Relay Box (STP-CBS)
Smart Controller (STP-SCI)
Guardian Series™ Controller (SPGC-220)
Pump Compatibility
up to 2 Hp
up to 2 Hp
up to 2 Hp
Horsepower Selection
Not Required
Not Required
Not Required
Standard THHN Wiring
YES
YES
YES
Primary/Secondary Pump Operation
NO
YES
YES
Alternating Pump Operation
NO
YES
YES
Communication Display
NO
YES, yellow flashing light
YES, yellow flashing light
YES, displays “IdLE”
Incoming Power Display
NO
YES, solid green light
Pump Running Display
YES, red pilot light
YES, green flashing light
YES, flashes “run”
Fault History Readout
NO
YES, flash last five faults
YES, displays last five faults
Fault Diagnostics
NO
YES, red flashing light
YES, red backlight display
Underload (dry run) Detection
NO
YES, 1 red flash
YES, flashes “UL”
Low Incoming Voltage Protection
NO
YES, 2 red flashes
YES, flashes “LI”
High Incoming Voltage Protection
NO
YES, surge protection
YES, flashes “HI”
YES, flashes “OL”
Overload (running) Detection
NO
YES, 3 red flashes
Overload (startup) Detection
NO
YES, 3 red flashes
YES, flashes “Lr”
Open Circuit Detection
NO
YES, 4 red flashes
YES, flashes “OC”
Extended Run Protection
NO
YES, 9 red flashes
YES, flashes “Er”
Relay Failure Protection
NO
YES, 10 red flashes
YES, flashes “rEL”
Audible Fault Alarm
NO
YES, reset/silence button
YES, separate silence button
Guardian Series™ Fixed Speed Pump Controller