2025 UL Ordering Catalog - Flipbook - Page 234
ORDERING INFORMATION CONTINUED
EVO™ 200 and EVO™ 400 Spare/Replacement Parts
Spare/Replacement Internal Boards
Spare/Replacement Hardware
Model
Description
Model
Description
FMSP-24MB
Spare/Replacement EVO™ 200 and EVO™ 400
Main Board
FMSP-LCD
Spare/Replacement LCD Display for an
EVO™ 200 / EVO™ 400
FMSP-SOM
Spare/Replacement SOM, standard features only,
no software options
FMP-24WIFI
FMSP-SOM-R
Replacement SOM, factory programmed with
existing software options
Replacement WiFi hardware for an existing
EVO™ 200, EVO™ 400, EVO™ 600, or EVO™ 6000,
includes 4.5" antenna
FMP-24FUSE
EVO™ 200 and EVO™ 400 replacement fuse kit
FMSP-UDP200
Spare/Replacement EVO™ 200 Input PCB
FMSP-UDP400
Spare/Replacement EVO™ 400 Input PCB
FMP-24TRMBLK
EVO™ 200 and EVO™ 400 replacement
terminal blocks
FMSP-24CVR
EVO™ 200 and EVO™ 400 without LCD
replacement cover
FMSP-24CVRWD
EVO™ 200 and EVO™ 400 with LCD
replacement cover
FMSP-24CBL1
Ribbon Cable - Display to Main Board
Note: The serial number of the existing EVO™ must be provided when ordering the
FMSP-SOM-R.
Printer Paper Supplies
Model
Description
FMP-EPPC
Case of 25 thermal external printer paper rolls
SPECIFICATIONS
Maximum tanks
monitored
6 (EVO™ 200)/14 (EVO™ 400)
Dimensions
H: 8" (205 mm), W:13 ¾" (350 mm),
D: 3¼" (83 mm)
Maximum sensor
input capacity
6 (EVO™ 200)/14 (EVO™ 400)
Alarm set points
High/low product, water, and temperature
Lines capacity
6 (EVO™ 200)/14 (EVO™ 400)
Technical Advantages
Inventory reconciliation/tank autocalibration/
flow rate monitoring (optional)
Dry contact
input channels
2
Measurements
Density, mass, and phase
separation measurement
Relay output channels
2
Notifications
Email and SMS
Connectivity
Ethernet, RS-232, RS-485, standard USB,
Mini-B USB, and WiFi (optional)
Programming
Conditions
Display type
7" (17.78 cm) color LCD touch screen
Printer type
External (network or USB)
Alarm
Internal audible alarm
LEDs
Alarm, warning, and power
Tank chart
correction points
7,500
Applicable liquids
Petroleum, chemicals, and waste
Level units
Inches, centimeters, and millimeters
Volume units
Gallons or liters (mass with density option)
Power requirements
110 to 240 VAC, 50/60 Hz, 2.6 Amps
Operating
temperature
32° to 104° F (0° to 40° C)
Humidity
0-95% non-condensing
234
Monitoring
Back-up generator
Support
MQTT, MODBUS™, XML, Veeder-Root®
Approvals
UL, cUL, ATEX, IECEx, GSA IT Security
– Third party certification of leak
Certifications
detection capabilities
– Third party verified “MATURE” security
posture level
EVO™ 200 & EVO™ 400 Series Consoles