EXPLOSION-PROOF TRANSDUCERS
For sites without intrinsically-safe conduits available, explosion-proof transducers may be used that share the conduit of pump wiring.
ORDERING INFORMATION
EVO™ Series Explosion-Proof Electronic Line Leak Detection Kits
Site Requirements
™
™
• EVO 550/5000 or EVO 600/6000
Model
Description
• TS-ELLD software options (TS-ELLD-G software option for
generator-specific applications)
TS-LS500E/2
2-line ELLD kit, includes (2) pressure transducer,
(1) leak generator kit (TS-ALCAL), (2) needle valve kit
(TS-ALNIP)
TS-LS500E/3
3-line ELLD kit, includes (3) pressure transducer,
(1) leak generator kit (TS-ALCAL), (3) needle valve kit
(TS-ALNIP)
TS-LS500E/4
4-line ELLD kit, includes (4) pressure transducer,
(1) leak generator kit (TS-ALCAL), (4) needle valve kit
(TS-ALNIP)
SPECIFICATIONS
TS-AFALNIP
Needle valve kit for E85 fuel
Pressure Transducer
Minimum Pressure Requirements
• TS-ACI, TS-420EXP, *TS-RLY Modules
* TS-RLY Module is not required when utilizing Turbine Pump Interface™ (TPI)
communications. Franklin Electric intelligent pump controllers required for TPI.
Dimensions
Item
6 1⁄4" × 2" NPT
Operating temperature
-40° F to 149° F (-40° C to 66° C)
Operating pressure
0 to 100 psi (0 to 689 kPa)
Sensor port fitting
2" female NPT
Sensor material
Anodized aluminum body and
stainless steel sensor
Approvals / Certifications
−
−
Value
Minimum Static
Pressure
UL, cUL, ATEX, IECEx
Third party certification of leak
detection capabilities
−
15 psi (1.034 bar) for gross 3.0 gph (11.4 lph)
hourly tests
−
17.5 psi (1.207 bar) for monthly 0.2 gph (0.8 lph)
precision tests
−
22.5 psi (1.551 bar) for annual 0.1 gph (0.4 lph)
precision tests
−
20 psi (1.379 bar) for learning lines
Line Volume Requirements - Gross Test
Pipework System
Gallons
Liters
Rigid pipework
2.5 – 312.2
9.5 – 1181.9
Flexible pipework
2.5 – 95.4
9.5 – 361.1
Hybrid pipework*
2.5 – 415.8
9.5 – 1574.0
UPP® pipework
2.5 – 176.0
9.5 – 666.2
* The capacity of the flexible component cannot exceed 95.4 gallons (361.1 liters)
Pipe Length Requirements
Pipe Diameter ID (in/cm)
Rigid (ft)
Rigid (m)
Flexible (ft)
Flexible (m)
Hybrid* (ft)
Hybrid* (m)
UPP® (ft)
UPP® (m)
1.0 (2.5)
62 – 7651
19 – 2332
62 – 2338
19 – 712
62 – 10191
19 – 3106
62 – 4313
19 – 1314
1.5 (3.8)
28 – 3400
9 – 1037
28 – 1039
9 – 316
28 – 4529
9 – 1380
28 – 1917
9 – 584
1.75 (4.4)
21 – 2498
7 – 762
21 – 763
7 – 232
21 – 3327
7 – 1014
21 – 1408
7 – 429
2.0 (5.1)
16 – 1912
5 – 583
16 – 584
5 – 178
16 – 2547
5 – 776
16 – 1078
5 – 328
2.5 (6.4)
10 – 1224
4 – 374
10 – 374
4 – 113
10 – 1630
4 – 496
10 – 690
4 – 210
3.0 (7.6)
7 – 850
3 – 260
7 – 259
3 – 78
7 – 1132
3 – 345
7 – 479
3 – 145
4.0 (10.2)
4 – 478
2 – 146
4 – 146
2 – 44
4 – 636
2 – 193
4 – 269
2 – 81
5.0 (12.7)
3 – 306
1 – 94
3 – 93
1 – 28
3 – 407
1 – 124
3 – 172
1 – 52
230