2025 UL Ordering Catalog - Flipbook - Page 16
SPECIFICATIONS
Liquid Compatibility
General
Variable
speed models
Only available in variable lengths
Max.
liquid viscosity
70 SSU at 60° F (15° C)
Fixed speed
Models are available in variable
length and fixed length options
STP
variable speed
STP variable speed models are UL and cUL listed
for fuel mixtures containing up to 10% ethanol, and
20% MTBE, 20% ETBE or 17% TAME with gasoline
Check valve
2¾" diameter fluorocarbon seal
constructed with cast aluminum body
and steel backing washer
STPAG
(AG compatible)
STPAG (AG compatible) models are UL listed for
fuel mixtures containing diesel fuel with up to 20%
Biodiesel, 100% Biodiesel, up to 85% ethanol with
gasoline, and 20% MTBE, 20% ETBE or 17% TAME
with gasoline
Pressure relief
valve
Available in four pressure relief settings, integral to
check valve. Standard model relieves at 40 psi and
resets above 35 psi
Syphon
Venturi-type syphon primer supplied with every
submersible. Syphon check valve and secondary
syphon sold separately
Variable speed
(non-AG)
All variable speed (non-AG) models can
also be used with diesel fuels, fuel oils, kerosene,
Avgas and jet fuels in a non-gelled pourable state
Air eliminator
Every submersible includes a tank return path with
one-way check valve to provide active air elimination
2 Hp fixed speed
2 Hp fixed speed models can also be used with
diesel fuels, fuel oils, kerosene, Avgas and jet fuels in
a non-gelled pourable state
Electrical
disconnect
Electrical yoke for positive contractor disconnect
during service
Wetted elastomers
All wetted elastomers are made of a high grade,
fluorocarbon compound
Approvals/
Certifications
−
−
cULus listed
Consult factory for applicable approvals
Variable Speed Pump Motor
Variable Speed Power Requirements
Variable
speed pumps
Can only be controlled by a MagVFC™ variable
frequency controller
VS2 models
Can operate with single- or three-phase incoming
power supply to the MagVFC™
4 Hp
Variable speed, two-stage centrifugal type
pump motor with integral, automatic, thermal
overload protection
Max. pressure
Selectable operating pressure on MagVFC™
between 24 psi and 42 psi deadhead
Incoming power
Incoming power supply to the MagVFC™
can be 200-250 VAC, 50 or 60 Hz
MagShell®
Available with MagShell® which results in 45%
increased flow area around motor
Outputs
MagVFC™ outputs a three-phase, variable
frequency signal, valid for FE PETRO® variable
speed pumps only
Fixed Speed Pump Motor
Max. line draw
MagVFC™ max. line draw: 20 Amps
2 Hp fixed speed
2 Hp fixed speed models require single-phase,
208-230 VAC, 60 Hz incoming power
Max. motor draw
7 Amps
Standard pressure
Standard pressure (M200, two-stage) model,
max. pressure = 36 psi
Fixed Speed Power Requirements
High pressure
High pressure (HM200, three-stage) model,
max. pressure = 45 psi
Incoming power
2 Hp fixed speed models require single-phase,
208-230 VAC, 60 Hz incoming power
MagShell®
Available with MagShell™ for 45% increased flow
area around motor
2 Hp fixed speed
2 Hp fixed speed models incorporate a starting and
running capacitor, with internal bleed resistor, rated
370 Volt, 40 microfarad
Single phase
SPGC-220 single-phase Guardian Series™
Controllers and STP-CBS single-phase control boxes
are available for 2 hp pump control
Max. motor draw
12 Amps
16
2 Hp Submersible Turbine Pumps