2025 EN Catalog-Interactive - Flipbook - Page 92
EXPLOSION-PROOF TRANSDUCERS
For sites without intrinsically-safe conduits available, explosion-proof transducers may be used that share the conduit of pump wiring.
SPECIFICATIONS
Pressure Transducer
Dimensions
6 1⁄4" x 2" NPT
Operating temperature
-40° F to 149° F (-40° C to 66° C)
Operating pressure
0 to 100 psi (0 to 689 kPa)
Sensor port fitting
2" female NPT
Sensor material
Anodized aluminum body and stainless steel sensor
Approvals & Certifications
–
UL, cUL, ATEX, IECEx
–
Third party certification of leak detection capabilities
Minimum Pressure Requirements
Item
Value
Minimum Pump Off Pressure
– 15 psi (1.034 bar) for gross 3.0 gph (11.4 lph) hourly tests
– 17.5 psi (1.207 bar) for monthly 0.2 gph (0.8 lph) precision tests
– 22.5 psi (1.551 bar) for annual 0.1 gph (0.4 lph) precision tests
– 20 psi (1.379 bar) for learning lines
Pipe Length Requirements
Pipe Diameter ID (in/cm) Rigid (ft)
Rigid (m)
Flexible (ft)
Flexible (m) Hybrid* (ft)
Hybrid* (m)
UPP® (ft)
UPP® (m)
1.0 (2.5)
19 – 2332
62 – 2338
19 – 712
19 – 3106
62 – 4313
19 – 1314
62 - 7651
62 – 10191
1.5 (3.8)
28 – 3400
9 – 1037
28 – 1039
9 – 316
28 – 4529
9 – 1380
28 – 1917
9 – 584
1.75 (4.4)
21 – 2498
7 – 762
21 – 763
7 – 232
21 – 3327
7 – 1014
21 – 1408
7 – 429
2.0 (5.1)
16 – 1912
5 – 583
16 – 584
5 – 178
16 – 2547
5 – 776
16 – 1078
5 – 328
2.5 (6.4)
10 – 1224
4 – 374
10 – 374
4 – 113
10 – 1630
4 – 496
10 – 690
4 – 210
3.0 (7.6)
7 – 850
3 – 260
7 – 259
3 – 78
7 – 1132
3 – 345
7 – 479
3 – 145
4.0 (10.2)
4 – 478
2 – 146
4 – 146
2 – 44
4 – 636
2 – 193
4 – 269
2 – 81
5.0 (12.7)
3 – 306
1 – 94
3 – 93
1 – 28
3 – 407
1 – 124
3 – 172
1 – 52
Line Volume Requirements - Gross Test
Pipework System
Gallons
Liters
Rigid pipework
2.5 - 312.2
9.5 - 1181.9
Flexible pipework
2.5 - 95.4
9.5 - 361.1
Hybrid pipework
2.5 - 415.8
9.5 - 1574.0
UPP® pipework
2.5 - 176.0
9.5 - 666.2
ORDERING INFORMATION
Site Requirements
• EVO™ 550/5000 or EVO™ 600/6000
• TS-ELLD software options (TS-ELLD-G software option for generator-specific applications)
• TS-ACI, TS-420EXP, *TS-RLY Modules
* TS-RLY Module is not required when utilizing Turbine Pump Interface™ (TPI) communications. Franklin Electric intelligent pump controllers required for TPI.
EVO™ Series Explosion-Proof Electronic Line Leak Detection Kits
92
Model
Description
TS-LS500E/2
2-line ELLD kit, includes (1) pressure transducer, (1) leak generator kit (TS-ALCAL), (2) needle valve kit (TS-ALNIP)
TS-LS500E/3
3-line ELLD kit, includes (2) pressure transducer, (1) leak generator kit (TS-ALCAL), (3) needle valve kits (TS-ALNIP)
TS-LS500E/4
4-line ELLD kit, includes (3) pressure transducer, (1) leak generator kit (TS-ALCAL), (4) needle valve kits (TS-ALNIP)
TS-AFALNIP
Needle valve kit for E85 fuel