2025 EN Catalog-Interactive - Flipbook - Page 8
CORROSION CONTROL™
WATER SEPARATOR
The Corrosion Control™ Water Separator provides proactive
in-tank corrosion control by removing tank-bottom corrosion
contributors including water and acid. The Water Separator uses
the flow of fuel created by a 4" FE PETRO® Submersible Turbine
Pump (STP) to generate a vacuum which suctions the tank
bottom. The separator vessel collects any water/acid mixture and
the clean fuel is directed back into the tank. The water/acid
mixture is then removed by a service technician, keeping the tank
clear of the harmful corrosion causing mixture.
HIGHLIGHTS
• Compatible with any new or existing FE PETRO® 4" STP.
SPECIFICATIONS
• Mounts to any 4" riser including either an STP riser or
probe riser.
Vessel capacity
3⁄4 gallon of water/acid (2.8 L)
• Element-free vessel has no filter to change, eliminating
ongoing replacement costs.
Eductor flow
8 GPM flow to drive suction pickup
(30 Lpm)
Suction pickup
1⁄4 GPM (0.9 Lpm)
• All stainless steel construction for corrosion resistance.
• Comprised of UL recognized components.
Minimum of 30" (0.76 m) of height
inside the tank sump.
• Height adjustable tank bottom suctioning kit can
accommodate tanks up to 10' in diameter.
• Automated control and monitoring is provided via an
EVO™ 600/6000.
• The EVO™ runs the Water Separator for 45 minutes after
each delivery as well as once a day during a non-peak
time to remove any water/acid mixture that drops to the
tank bottom.
Accessible 4" port in the tank manway
Containment
Sump
Requirements
High-voltage conduit for solenoid wiring
Intrinsically safe conduit for Water
Separator probe
• During scheduled operation, the EVO™ opens the Water
Separator's solenoid valve to allow fuel to begin flowing
through the separator vessel while a flow switch monitors
the system for positive flow.
• An integrated LL3 Probe monitors separator operation and
provides a notification to empty the vessel via the EVO™.
• Short profile to fit in many different sumps.
At least 11" (280 mm) envelope for
vessel and adjacent piping
EVO™ 600 or EVO™ 6000
EVO™ Series latest firmware version
Tank Gauge
Requirements
Access to in-tank product level readings
(for delivery events and recirculation
runtime)
1 open Relay Module port (for solenoid)
1 open UDP Module input, Probe
module input, or MSH input
(for vessel probe)
SYSTEM
COMPONENTS
Add these Corrosion Control™
System items to your site
to proactively prevent and
detect corrosion.
8
EVO™ 600 OR
EVO™ 6000
CORROSION
DETECTION SENSOR
MULTIPLEXING
SENSOR HUB™
DESICCANT
PACK
ADVANCED
PROTECTION STP