STP-DHIB DISPENSER
HOOK ISOLATION
The FE PETRO® dispenser hook isolation device prevents
electrical feedback between dispenser hook circuits as
required by most electrical codes.
HIGHLIGHTS
• Optically isolates inputs from up to eight dispensers
preventing damage to dispenser relay boards caused by
cross-phasing.
• Prevents electrical feedback between dispenser hook
circuits during periods of maintenance and service as
required by NEC 514-3, 2002 and other international codes.
• Can be supplied factory-wired in tandem with the FE
PETRO® smart controller or the FE PETRO® standard
control box.
• Eliminates false STP run due to voltage leakage of multiple
dispensers connected in parallel.
• Fuse-protected output to submersible pump controller.
• The STP-DHIB can retrofit to any existing site.
8 1⁄2" x 5" x 3"
(215 mm x 127 mm x 76 mm)
Inputs
Eight optically isolated inputs
from dispenser
STP-DHIB
240 V 30 V A input from supply, eight
240 V 10 mA inputs from dispensers
Model
Description
402312922
STP-DHIB-SCI combo DHI with factory-wired STP-SCI
402313922
STP-DHIB-CBBS, combo DHI with factory-wired
STP-CBBS single-phase control box
5800300200
STP-DHIB, isolates up to eight, 120 Volt dispenser handles
DHIB models are compatible with FE PETRO® submersible pump controllers and
competitive pump controller makes accepting 240 Volt dispenser hook signal.
DHIB models can be connected together for products with more than eight
dispenser handle inputs.
DHI Repair Parts and Accessories
Model
Description
223243103
DHI fast-acting fuse, 250 VAC, 1 Amp
223885931
DHIB circuit board, 240 Volt dispenser hook signal
DHIB with 240 VAC Dispenser Hook Signal Wiring Diagram
INPUT 110V
NEUTRAL
OUTPUT 110V
NEUTRAL
*
TO ADDITIONAL STP-DHI(S)
POWER SUPPLY & NEUTRAL
TERMINALS
*
TO ADDITIONAL STP-DHI(S)
HOOK OUT TERMINALS
RV5
RV5
NEUTRAL WIRE TERMINAL
120 VOLT
SUPPLY WIRE TERMINAL
DISPENSER #1 (SUPPLY & NEUTRAL),
TYPICAL WIRING FOR ALL DISPENSERS
*Wiring
is polarity-sensitive when multiple units are connected together.
*
Wiring is polarity-sensitive when multiple units are connected together.
234
Enclosure size
One STP-DHIB required per product
grade for up to eight dispensers
ORDER INFORMATION
FUSE, 250 VAC, 1 AMP
(FAST-ACTING TYPE)
SPECIFICATIONS
Output fuse rating
250 V 1A, fast acting
Surge protection
300 Volt surge protection
Max.ambient
temperature rating
120° F
LEDs
LEDs indicate when source power is
applied and dispenser hook signals
are present
Compatibility
Compatible with any submersible
pump controller
Approvals &
Certifications
• Consult factory for applicable
approvals
• ISO 9001 Certified Manufacturer