2025 EN Catalog-Interactive - Flipbook - Page 222
SPECIFICATIONS
-
Max. liquid viscosity: 70 SSU
at 60°F (15°C).
-
Standard models are listed for fuel
mixtures containing up to 10%
ethanol with gasoline, and 20%
MTBE, 20% ETBE, or 17% TAME
with gasoline.
Liquid
Compatibility
-
STPAG models are compatible for fuel
mixtures containing diesel fuel with
up to 20% biodiesel, 100% biodiesel,
up to 85% ethanol with gasoline, and
20% MTBE, 20% ETBE, or 17% TAME
with gasoline.
1½ hp fixed speed models can also
be used for fuel mixtures containing
up to 5% biodiesel with diesel fuels,
fuel oils, kerosene, Avgas and jet fuels
in a non-gelled, pourable state.
Pump Motor
1½ hp fixed speed, 2875 rpm,
multi-stage centrifugal type pump
motor with integral, automatic,
thermal overload protection.
Models
11/2 hp fixed speed models are
available in variable length and
fixed length options
Check valve
70 mm diameter fluorocarbon seal
constructed on cast aluminum
body and steel backing washer
Pressure relief valve
Available in four pressure relief
settings, integral to check valve.
Standard model relieves at 2.76
bar and resets above 2.41 bar.
Syphon
Venturi-type syphon primer
supplies with every submersible.
Syphon check valve and secondary
syphon sold separately
Air eliminator
Every submersible includes a
tank return path with one-way
check valve to provide active
air elimination
Electrical yoke for positive
contractor disconnect
during service.
-
All wetted elastomers are made of a
high grade, fluorocarbon compound.
-
150B models require single-phase,
200-250 VAC, 50 Hz incoming power.
-
150B models incorporate a starting
and running capacitor, with internal
bleed resistor, rated 440 Volt,
15 microfarad.
Electrical
disconnect
SPGC-220 single-phase Guardian
controllers and STP-CBBS single-phase
control boxes are available for
150B control.
Approvals &
Certifications
Power
Requirements
-
150C models require three-phase,
380—415 V,50 Hz incoming power.
-
TPGC-380 three-phase Guardian
controllers and STP-CBB three-phase
magnetic starters available for
150C control.
-
Consult factory for
applicable approvals.
-
Franklin Electric is an ISO 9001
Certified Manufacturer.
1½ HP Fixed Speed Turbine Performance Chart
(STP150C)
50
45
45
40
40
35
35
Total Head in Meters
Total Head in Meters
(STP150B)
50
30
25
20
25
20
15
15
10
10
5
5
0
0
0
50
100
150
200
250
300
350
Flow in Liters per Minute (LPM)
Note: Performance based on pumping solvent (0.78 specific gravity). Pressure
is taken at the manifold discharge outlet. Fixed Speed 1.5 HP was powered by
Single-Phase, 50 Hz, 250 Volt incoming supply.
222
30
0
50
100
150
200
250
300
350
Flow in Liters per Minute (LPM)
Note: Performance based on pumping solvent (0.78 specific gravity). Pressure
is taken at the manifold discharge outlet. Fixed Speed 1.50 HP was powered by
Three-Phase, 50 Hz, 415 Volt incoming supply.