2025 EN Catalog-Interactive - Flipbook - Page 218
SPECIFICATIONS
-
200B models require single-phase,
200-250 VAC, 50 Hz incoming power.
-
200B models incorporate a starting and
running capacitor, with internal bleed
resistor, rated 440 Volt, 40 microfarad.
-
-
2 hp fixed speed, 2875 rpm, multistage centrifugal type pump motor with
integral, automatic, thermal overload
protection.
-
Available with MagShell® for 45%
increased flow area around motor.
Pump Motor
SPGC-220 single-phase Guardian
controllers and STP-CBBS single-phase
control boxes are available for
200B control.
Models
2 hp fixed speed models are available in
variable length and fixed length options
-
200C models require three-phase,
380-415 VAC,50 Hz incoming power.
Check valve
-
TPGC-380 three-phase Guardian
controller and STP-CBB three-phase
magnetic starter available for
200C control.
70 mm diameter fluorocarbon seal
constructed on cast aluminum body and
steel backing washer
Pressure
relief valve
Available in four pressure relief settings,
integral to check valve. Standard model
relieves at 2.76 bar and resets above
2.41 bar.
Syphon
Venturi-type syphon primer supplies with
every submersible. Syphon check valve
and secondary syphon sold separately
Air eliminator
Every submersible includes a tank return
path with one-way check valve to provide
active air elimination
Electrical
disconnect
Electrical yoke for positive contractor
disconnect during service.
Power
Requirements
-
Max. liquid viscosity: 70 SSU at 60° F
(15° C).
-
Standard STP models are listed for fuel
mixtures containing up to 10% ethanol
with gasoline, and 20% MTBE, 20%
ETBE or 17% TAME with gasoline.
-
STPAG (AG compatible) models are for
fuel mixtures containing diesel fuel with
up to 20% biodiesel, 100% biodiesel, up
to 85% ethanol with gasoline and 20%
MTBE, 20% ETBE or 17% TAME with
gasoline.
Liquid
Compatibility
-
2 hp fixed speed models can also be
used for fuel mixtures containing up to
5% biodiesel with diesel fuels, fuel oils,
kerosene, Avgas and jet fuels in a
non-gelled pourable state.
-
All wetted elastomers are made of a
high grade, fluorocarbon compound.
Approvals &
Certifications
-
Consult factory for
applicable approvals.
-
Franklin Electric is an ISO 9001
Certified Manufacturer.
2 hp Fixed Speed Turbine Performance Chart
(STP200C)
50
45
45
40
40
35
35
Total Head in Meters
Total Head in Meters
(STP200B)
50
30
25
20
25
20
15
15
10
10
5
5
0
0
0
50
100
150
200
250
300
350
Flow in Liters per Minute (LPM)
Note: Performance based on pumping solvent (0.78 specific gravity). Pressure
is taken at the manifold discharge outlet. Fixed Speed 2.00 HP was powered by
Single-Phase, 50 Hz, 250 Volt incoming supply.
218
30
0
50
100
150
200
250
300
350
Flow in Liters per Minute (LPM)
Note: Performance based on pumping solvent (0.78 specific gravity). Pressure
is taken at the manifold discharge outlet. Fixed Speed 2.00 HP was powered by
Three-Phase, 50 Hz, 415 Volt incoming supply.