2025 EN Catalog-Interactive - Flipbook - Page 101
DISCRIMINATING DISPENSER
SUMP SENSOR (DDS)
The DDS is a discriminating dispenser sump sensor that detects the presence
of liquid and hydrocarbons in dispenser containment sumps.
HIGHLIGHTS
ORDERING INFORMATION
• Uses magnetic float switches to detect liquid at two levels.
Model
Description
FMP-DDS-UD
Discriminating dispenser sump sensor with
simple apparatus connection
(EVO™ 200/400, EVO™ 600/6000)
FMP-DDS
Discriminating dispenser sump sensor
(EVO™ 550/5000, EVO™ 600/6000)
TSP-KS
Unistrut™ mounting kit
• Innovative polymer strip detects hydrocarbons along sensor.
• Compatible with common fuels and chemicals.
• Detects liquid at 1½" (38 mm) from base.
• Digitally encoded status information sent from
microcomputer to the EVO™ console.
• Variety of mounting methods possible depending on
location. Bracket provided for quick installation.
FUEL MANAGEMENT
SYSTEMS
• Alarms to indicate liquid in sump, hydrocarbon detected,
sump full, and sensor malfunction.
Note: The FMP-DDS-UD communicates with EVO™ 600/6000 using the
Universal Device Protocol Module (FMP-UDP9) or Probe Module (TS-PRB). The
FMP-DDS communicates with the EVO™ 550/5000 and EVO™ 600/6000 using
the 3-Wire Sensor Module (TS-3WSNS).
• An additional wire connection is available for adding a
2-wire simple apparatus to the FMP-DDS-UD sensor.
• Software in the EVO™ Series will recognize the additional
simple apparatus and monitor both inputs.
DISCRIMINATING TURBINE
SUMP SENSOR (DTS)
The DTS is a discriminating turbine sump sensor that detects the presence
of liquid and hydrocarbons in tank containment sumps.
HIGHLIGHTS
ORDERING INFORMATION
• Uses magnetic float switches to detect liquid at two levels.
Model
Description
FMP-DTS-U
Discriminating turbine sump sensor
(EVO™ 200/400, EVO™ 600/6000)
FMP-DTS
Discriminating turbine sump sensor
(EVO™ 550/5000, EVO™ 600/6000)
TSP-KS
Unistrut™ mounting kit
• Innovative polymer strip detects hydrocarbons along sensor.
• Compatible with common fuels and chemicals.
• Detects liquid at 1½" (38 mm) from base.
• Digitally encoded status information sent from
microcomputer to the EVO™ console.
• Alarms to indicate liquid in sump, hydrocarbon detected,
sump full, and sensor malfunction.
Note: The FMP-DTS-U communicates with EVO™ 600/6000 using the Universal
Device Protocol Module (FMP-UDP9) or Probe Module (TS-PRB). The FMP-DTS
communicates with the EVO™ 550/5000 and EVO™ 600/6000 using the 3-Wire
Sensor Module (TS-3WSNS).
101