2025 EN Catalog-Interactive - Flipbook - Page 100
SENSORS
No matter what the monitoring application is, Franklin
Electric offers a sensor solution tailored to the specific
requirements of each application.
SENSOR SELECTION GUIDE
Does your application require
the need to tell the difference
between fuel and water?
Does your application only
require the need detect any
type of liquid?
What type of Automatic Tank
Gauge (ATG) are you
connecting to?
Discriminating Sensors are able to
detect and send an alarm signal if the
presence of liquid is detected inside
and can also differentiate between
liquid and hydrocarbons.
Non-Discriminating Sensors are able
to detect and send an alarm signal if
the presence of liquid is detected
inside of a containment space.
Select the appropriate model number
of sensor that's compatible with your
ATG using the chart below.
Sensor
Discriminating
Dispenser Sump
Sensor
Discriminating
Turbine Sump
Sensor
Discriminating
Magnetostrictive
Sump Sensor
Discriminating
Capability
Non-Discriminating
-
Turbine Sump
Applications
-
Dispenser Sump
Applications
-
Universal Liquid
Sensor
Universal
Hydrostatic
Sensor
Electro-Optic
Interstitial
Sensor
-
-
-
Discriminating
Interstitial
Sensor
Hydrostatic
Interstitial
Sensor
Corrosion
Detection
Sensor
Desiccant Pack
Sensor
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Tank Interstitial
Space Applications
-
-
-
-
Tank Ullage
Applications
-
-
-
-
-
-
-
-
Position Sensitive
(Tamper Protection)
-
-
-
-
-
-
-
Hydrostatic
Monitoring
Capability
-
-
-
-
-
-
EVO™ 200 / 400
Model Number
FMP-DDS-U
FMP-DTS-U
TSP-DMS
FMP-ULS
FMP-UHS
FMP-EIS-U
FMP-DIS-U
EVO™ 550 /5000
Model Number*
FMP-DDS
FMP-DTS
TSP-DMS
FMP-ULS
FMP-UHS
FMP-EIS
EVO™ 600 / 6000
Model Number*
FMP-DDS,
FMP-DDS-U
FMP-DTS
FMP-DTS-U
TSP-DMS
FMP-ULS
FMP-UHS
Dispenser sump
applications
requiring
discriminating
capabilities
Turbine sump
applications
requiring
discriminating
capabilities
Containment
sump applications
requiring
discriminating
capabilities with
tamper protection
regulations in
place
Containment
sump and steel
double wall tank
applications
Brine-filled
double wall
containment
sump and tank
applications
Typical
Application
-
-
-
-
-
-
-
FMP-HIS-U
FMP-HIS-XL-U
FMP-CDS-U
FMP-DPS-U
FMP-DIS
FMP-HIS
FMP-HIS-XL
-
-
FMP-EIS
FMP-EIS-U
FMP-DIS
FMP-DIS-U
FMP-HIS
FMP-HIS-XL
FMP-HIS-U
FMP-HIS-XL-U
FMP-CDS-U
FMP-DPS-U
Dry double
wall steel and
wrap-around
fiberglass tank
applications
Dry double
wall steel and
wrap-around
fiberglass tank
applications
requiring
discriminating
capabilities
Brine-filled
double wall tank
applications
requiring high
brine vs. low
brine detection
Monitoring
for corrosive
environments
Monitoring
remaining life of
the Desiccant
Pack(s)
EVOTM 600/6000, EVOTM 550/5000 may support additional sensors. Sensors with "-U" that are used with the EVO™ 600/6000 wire to either a Universal Device Protocol
Module (FMP-UDP9) or a Probe Module (TS-PRB). FMP-DDS, FMP-TDS, FMP-EIS, FMP-DIS, FMP-HIS and FMP-HIS-XL all require a 3-Wire Sensor Module (TS-3WSNS).
100
-